h2x
Create
Log in
Roadmap
Feedback
Feature Requests
Changelog
Log in to your h2x account to give feedback
Log In
Boards
Feature Requests
Powered by Canny
Feature Requests
Details
Category
Select a category
Showing
Trending
Sort
Trending
Top
New
Filter
Under Review
Planned
In Progress
Complete
posts in
All Categories
All Categories
Heating (Hydronic) (68)
Water/Plumbing (33)
Ventilation (Ductwork) (33)
Exports (40)
Usability (43)
Settings (18)
General (49)
3D View (16)
Fixed pressure drop options in ventilation
Allow fixed pressure drop through ductwork equipment such as attenuators, rather than just k values/ zeta values
0
17
Room Transfer Ducts
Would love to see room transfer ducts for return air
0
5
Pressure drop rate for ducting similar to piping.
Currently in H2X, there is no pressure drop rate (Pa/m) to show in the result, only pressure drop(Pa) for the whole duct length. We need to calculate them using duct sizer every time.
0
11
Add Efficiency to MVHR without turning on Heating/Cooling
Ability to add MVHR that allows you to input the efficiency without the need to turn on heating/cooling as this isn't required for most MVHR. You can currently do this by using the "percentage of ventilation heat loss recovered" under the calculation method settings but this won't work in projects where you have multiple MVHR or different ventilation system within the project. I have detailed this explanation in my email to Martins (CC Michael and Jordan) dated 10/11/2025
3
1
Ability to split Intake and Exhaust loads through a Manifold in Ventilation Systems
0
2
Ability to set a manual intake and exhaust value and not just have it dependent on the supply and extract values.
1
5
Set supply air to intake on an AHU
I would like to be able to connect supply air MVHR to an AHU intake to enable the 2 systems to be combined and operate together. The calculation should also be able to complete when they are connected
0
3
Add references to grilles and diffusers
Currently grilles and diffusers can't be referenced like AHUs. This would assist in providing mark-ups for drafting. This reference should show up instead of the green diffuser text that is currently shown. Maybe these references could be auto populated as they are placed.
1
7
Plastic ductwork for Apartment ductwork design
As we do a lot of residential schemes, it would be good if there was a library of plastic ductwork and fittings which included sizes 204x60mm and 220x90mm.
0
5
HRV semi ridged fixed ducting sizes.
Have the ability to select the simi ridged duct sizes for HRV systems, particularly the manifold box connections and fix the sizes so H2x doesn't over ride them - 2 dust into one HRV diffusers would be great also.
1
1
Load More
→