Domestic Hot Water Return Pumps & TBVs
I'd like to be able to assess the impact of using thermo balancing valves rather than just standard heat loss and regulating valves when sizing domestic hot water return pumps and pipework. Flow and pressure requirements are normally higher than using heat loss method - CIBSE Guide G details the formula for this.
0
1
remove/ ability to delete hot feed to Washing machine and dishwasher
To stop false system errors and client questions the ability to delete the hot service would be good.
0
11
Manual override of pressure drop on Valves
The ability to manually specify the pressure drop on a mixing valve or for H2X to recognise when it is good practice to increase the size of the valve to match calculated pipe sizes.
1
4
Pressure Nodes Visibility
When reconfiguring a layout with nodes on the system. Having the node centre a colour other than grey would assist in finding them. Using the Multi pipe tool doesn't make it easier to find either. The cross hairs has to be exactly on the node to connect. Having the multi pipe circle pick up the nodes would make reconnecting layouts easier.
0
1
Ability to override the wastewater pipe grade per pipe
Just like pipe diameter
0
1
DHW Heat Exchanger
Incorporate a Rheem 50kW Heat Exchanger (0191750) that can be used on two domestic hot water loops for pressure zoning on high rise.
0
1
Bill of Materials PEX hot and cold separation
It's very common in PEX installations that hot and cold lines are installed using appropriate colored PEX (red & blue). Having these as separate entries in bill of materials allows more accurate purchase of specific PEX for the job.
0
1
Specify offset distances for piping
It would be great to be able to specify the offset distance of piping, or even specify pipe length, to allow for consistency throughout drawings.
0
2
Tank infill
The ability to set the incoming flowrate to a tank on the basis of an infill time
0
4
Warm Water System wait times
Have the ability to show 'Warm Water Wait times' to fixtures when connected to a warm water system
0
1